Air Hydraulic Tool Change Unclamping Cylinder( Intensifiers) – HUC Series

Hydraulic Booster Cylinder

  • Can be used with or without Coolant Thru Spindle(CTS)
  • Use with hydraulic power booster(oil/air) or hydraulic power unit(oil only)
  • Enlarged air/oil outlet design for faster tool changing
  • Equipped with rotation resistance and sensors for easy adjusting
  • High endurance seals facilitate low oil consumption and not easy to cold
  • Rod and cylinder body specially protected against rust and corrosion
DOWNLOAD

Air Hydraulic Tool Change Unclamping Cylinder( Intensifiers) – HUC Series Catalog

HUC-115N11 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115N114Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor11 mmCPC-R32 / ISO VG32
HUC-115P11 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115P114Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D111 mmCPC-R32 / ISO VG32
HUC-115R11 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115R114Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N11 mmCPC-R32 / ISO VG32
HUC-115N13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115N134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor13 mmCPC-R32 / ISO VG32
HUC-115P13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115P134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D113 mmCPC-R32 / ISO VG32
HUC-115R13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-115R134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ115 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N13 mmCPC-R32 / ISO VG32
HUC-120N12 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120N124Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor12 mmCPC-R32 / ISO VG32
HUC-120P12 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120P124Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D112 mmCPC-R32 / ISO VG32
HUC-120R12 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120R124Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N12 mmCPC-R32 / ISO VG32
HUC-120N14 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120N144Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ140 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor14 mmCPC-R32 / ISO VG32
HUC-120P14 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120P144Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ140 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D114 mmCPC-R32 / ISO VG32
HUC-120R14 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120R144Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ140 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N14 mmCPC-R32 / ISO VG32
HUC-125N10 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125N104Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor10 mmCPC-R32 / ISO VG32
HUC-125P10 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125P104Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D110 mmCPC-R32 / ISO VG32
HUC-125R10 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125R104Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N10 mmCPC-R32 / ISO VG32
HUC-125N13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125N134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor13 mmCPC-R32 / ISO VG32
HUC-125P13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125P134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D113 mmCPC-R32 / ISO VG32
HUC-125R13 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-125R134Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Through spindle coolant systemΦ125 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N13 mmCPC-R32 / ISO VG32
HUC-120N20 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120N204Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Without through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)without sensor20 mmCPC-R32 / ISO VG32
HUC-120P20 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120P204Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Without through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Omron/E2E-X2D120 mmCPC-R32 / ISO VG32
HUC-120R20 Product NameActuation PressureApplicable SpindleCylinder DiameterOutput ForceSensorStrokeWorking Fluid Compare
HUC-120R204Mpa - 9.5Mpa(40kgf/cm2 - 95kgf/cm2)Without through spindle coolant systemΦ120 mm155Mpa - 760Mpa(1550kgf/cm2 - 7600kgf/cm2)Riko/RN04-N20 mmCPC-R32 / ISO VG32

This site uses cookies to improve your browsing experience. we’ll assume you’re OK to continue. If you want to read more about this, please click PRIVACY, thank you.